Home > Technologies > Search by Technology & Service > Medical Chemical Manufacturing System > Working Conditions Improvement Support
This service helps you improve the working conditions on the manufacturing floor with cutting-edge localized exhaust systems.



Exhaust system with an auxiliary jet
(conceptual image)

Without an auxiliary jet
(conceptual image)
By equipping the exhaust ports of our exhaust systems to include exhaust hoods with auxiliary jets, our systems prevent air taken-in from dispersing, to achieve a higher air concentration, which in turn allows for exhaust with minimal air volume. Tests conducted in our laboratory have demonstrated that this system delivers a higher exhaust efficiency when distanced from the emission source.
Additionally, by combining this system with our VOC exhaust treatment system it will contribute to not only the improvement of working conditions, but also the environment around the factory.

D: The distance from the emission source when the diameter of the exhaust port is one.
5D represents the diameter multiplied by five, and 8D represents the diameter multiplied by eight.